Language
Shopping Cart

MT-NET-BX2 Controller 8 DIN 28 I/O

SKU
MT-NET-BX2*02
Get a Quote
MultiNet programmable controller without display 28 I/O, Ethernet, 2 Modbus (RS485)
ANALOGUE INPUTS
Configurable in pairs

DIGITAL INPUTS
2 optoisolated digital inputs (Pulse count + Frequency reading)
Note: it measures a signal with a maximum frequency of 2kHz.
The digital inputs can be used as pulse counters.
The duration of the pulse (positive or negative) must be greater than 0.15ms.

6 normal optoisolated digital inputs
Working voltage + 24Vac / dc.
Current consumption max. 5mA
The digital inputs can be used as pulse counters. The pulse length (both positive and negative) must be greater than 20ms (if DI3, DI4) or 40ms (if DI5, DI6, DI7, DI8)

ANALOGUE OUTPUTS
0-10V / 4-20mA / ON-OFF

DIGITAL OUTPUTS
2 configurable outputs:
• 4..20mA current modulation,
• ON-OFF current: the current (ON) is 25mA, the current (OFF) is 0mA .. (They can drive DGSRMVs)
• Voltage modulation 0..10V,
Range: 0..1000, Accuracy: 1% fs, Resolution: 1 digit, Load impedance:> 700Ω
• PWM mode: Frequency from 1Hz to 2000Hz (1Hz accuracy), Duty Cycle from 0.0% to 100.0% (accuracy 0.1%), Open Collector output, 30mA, + 24Vdc max.
More Information
Power supply 24 V AC, 24 V DC
Power consumption Max. [VA] 23
Power consumption [W] 12
Analog outputs 4
Digital outputs 8
Analog inputs 8
Digital inputs 8
Controller type Programmable
IP 20
Communication protocol Modbus RTU/ASCII, Modbus TCP/IP