Language
Shopping Cart

Compare Products

Print This Page
Compare Products
Remove Product Remove Product Remove Product Remove Product Remove Product Remove Product Remove Product Remove Product Remove Product Remove Product Remove Product
Product
SKU
2TBB15
2TBB15T
2TGB15B
2TGB15F
MVT503*02
MVP230
iSMA-B-8I
iSMA-B-MIX18
iSMA-B-24I
iSMA-B-MAC36PRO
Description
The 2TBB and 3-way 3TBB two-way valves can be used for the control or interception of fluids in air conditioning, heating and heating systems, civil and industrial, in machines for the heat treatment of products and in systems for domestic hot water. The 3-way valves must be used exclusively as mixers. Never use the angled pathway for adjustment.
The 2TBB.T two-way valves 3TBB.T can be used for the control or interception of fluids in air conditioning, heating and heating systems, civil and industrial, in machines for the heat treatment of products and in water systems. hot sanitary. The 3-way valves must be used exclusively as mixers. Never use the angled corner for adjustment.
Can be driven with MVT203, MVT403 and MVT503 actuators.
The valves of the 2-3TGB.B series can be used for the control or interception of fluids in air conditioning, heating and heating systems, civil and industrial, and in machines for the heat treatment of products. The 3-way valves must be used exclusively as mixers. Valve body in gray cast iron (EN1561 GJL-250) and brass plug (EN12164 CW614N) with an equal percentage on the direct and linear path on the corner road and perfect seal with teflon gasket; the permissible temperature for the fluids is -5 °C / 140 °C.
The 2-3TGB.B series valves are made of cast iron body and brass plug and can be motorized with MVE.S actuators. Used for the control or interception of fluids in air conditioning, heating and heating systems, civil and industrial, and in machines for the heat treatment of products. The 3-way valves must be used exclusively as mixers. Valve body in gray cast iron (EN1561 GJL-250) and brass plug (EN12164 CW614N) with an equal percentage on the direct and linear path on the corner road and perfect seal with teflon gasket; the permissible temperature for the fluids is -5 °C / 140 °C. The stainless steel spindle seal is made with teflon gaskets compatible with water and water and glycol mixtures in the specified temperature range.
The MVT actuator is used in combination with pull / push valves or in conjunction with fixed stroke valves with return spring. Allows the control of the flow of hot and cold water in two and four-pipe terminal units, zone plants, solar systems, small post-heating and dehumidification batteries.

The MVT actuator is bi-directional electric. The valve stem is driven by a synchronous motor and a gear train optimized for high performance and minimum noise emissions.
The actuator is equipped with a limit force mechanism that interrupts the motor power supply when the force of 300N is reached.
If configured as a car ride, the proportional models software allows the learning of the stroke, so it can be used on any valve as long as it respects the maximum stroke limit allowed.

MVT503S is also equipped with 3 Signaling LEDs.
MVP are electro-thermal actuators and are controlled by an on-off signal or, 24Vac models only, also by pulse width modulation. Actuators are powered by the on-off control signal; power supply heats the thermostatic actuator that is moving the valve stem.
Multiprotocol I/O Module in a Compact Size
Powerful I/O module that works as a remote I/O over a serial port with open protocols, BACnet MS/TP and Modbus RTU/ASCII. The module is equipped with 8 digital inputs, which makes it a perfect monitoring device. A compact size and ease of installation allow the module to be fitted even into limited space installations.

8 Digital Inputs
Dry contact inputs were made for monitoring. 100 Hz fast pulse counter with override function saves the real-time values to the EEPROM memory.

Simplified Configuration and Commissioning Process
The module allows for seamless configuration over BACnet, Modbus, or dedicated free of charge tool. The ability to be powered from a USB port facilitates local testing and a straightforward updating process, and the high-end RS485 transceiver allows up to 128 devices to communicate reliably with the client on a single bus.

Quality and Reliability Confirmed by Certificates
iSMA CONTROLLI is a long-standing member of the BACnet community. The experience in developing high quality products and the BTL (BACnet Test Laboratory) certification confirm the excellent performance of communication using the BACnet protocol.
Reliability of operation is confirmed by UL testing, certified by Underwriters Laboratories.


Technical Specification

Hardware Specification
RS485 interface
mini USB type B interface
Status LED indicators
DIN rail mounted

Inputs
8 Digital Inputs (DI)
Dry contact inputs
Fast pulse counter up to 100 Hz saved in the EEPROM memory

Communication
BACnet MS/TP
Modbus RTU/ASCII
Free software iSMA Configurator
Dedicated Niagara Framework modules

Power Supply
24 V DC ± 20%
24 V AC ± 20%
Multiprotocol Module with a MIX of I/O's - the Ultimate Controller Extension
Powerful I/O module that works as a remote I/O over a serial port with open protocols, BACnet MS/TP and Modbus RTU/ASCII. Open protocols standard offers the versatility of installing the modules in both new and existing facilities, whether it is a system expansion or a retrofit. The most popular types of inputs and outputs are MIXed in a space-saving design and allow the module to be a versatile controller extension, whether in a small or large facility.

5 Universal Inputs
Support for over 20 types of temperature sensors and voltage, resistance, current, and dry contact measurements on each universal input.

5 Digital Inputs
Dry contact inputs - made for monitoring. 100 Hz fast pulse counter with override function saves the real-time values to the EEPROM memory.

4 Digital Outputs
Digital outputs equipped with normally open 3 A relays allow for a direct control without additional relays.

4 Analog Outputs
0-10 V DC control with 10 mA accuracy, PWM modes, and a maximum load of up to 20 mA to power external relays makes the output suitable for a variety of scenarios.

Simplified Configuration and Commissioning Process
The module allows for seamless configuration over BACnet, Modbus or dedicated free of charge tool. The ability to be powered from a USB port facilitates local testing and a straightforward updating process, and the high-end RS485 transceiver allows up to 128 devices to communicate reliably with the client on a single bus.

Quality and Reliability Confirmed by Certificates
iSMA CONTROLLI is a long-standing member of the BACnet community. The experience in developing high quality products and the BTL (BACnet Test Laboratory) certification confirm the excellent performance of communication using the BACnet protocol.
Reliability of operation is confirmed by UL testing, certified by Underwriters Laboratories.


Technical Specification

Hardware Specification
RS485 interface
mini USB type B interface
Status LED indicators
DIN rail mounted
18 I/Os onboard

Inputs
5 Universal Inputs (UI)
Temperature input in Celcius degrees: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000 0C, Ni 1000 20C, Ni1000 LG 2
Temperature input in Fahrenheit degrees: 10K Type2, 10K type3, 20K, 3K, PT 1000, Ni 1000 32F, Ni 1000 70F
Resistive input 0-1000 kΩ
Voltage input 0-10 V DC
Current input 0-20 mA
Dry contact input

5 Digital Inputs (DI)
Dry contact inputs
Fast pulse counter up to 100 Hz saved in the EEPROM memory

Outputs
4 Digital Outputs (DO)
NO relay output
Resistive load max. 3 A @ 230 V AC / 30 V DC
Inductive load max. 75 VA @ 230 V AC / 30 W @ 30 V DC

4 Analog Outputs (AO)
Output 0-10 V DC maximum load up to 20 mA
PWM: 0.01 Hz, 0.1 Hz, 1 Hz, 10 Hz, 100 Hz

Communication
BACnet MS/TP
Modbus RTU/ASCII
Free software iSMA Configurator
Dedicated Niagara Framework modules

Power Supply
24 V DC ± 20%
24 V AC ± 20%

Multiprotocol I/O Module with a MAX number of Digital Inputs - a powerful addition to any building automation system
Digitalize buildings with reduced engineering time using the powerful 24 digital inputs module, which works as a remote I/O over the serial port with open protocols: BACnet MS/TP, and Modbus RTU/ASCII. The module is designed for data monitoring in data centers and HVAC applications. Open protocols standard offers the versatility of installing the modules in both new and existing facilities, whether it is a system expansion or a retrofit. The maximum number of the most popular types of inputs or outputs allows the module to be a versatile controller extension, whether in a small or large facility.

24 Digital Inputs
Dry contact inputs - made for monitoring. 100 Hz fast pulse counter with override function saves the real-time values to the EEPROM memory.

Simplified Configuration and Commissioning Process
The module allows for seamless configuration over BACnet, Modbus, built-in web server, or dedicated free of charge tool. The ability to be powered from a USB port facilitates local testing and a straightforward updating process. Two Ethernet ports working in a switch mode allow for daisy chaining of multiple modules over the RJ45, which facilitates the cabling process and reduces engineering time.

Quality and Reliability Confirmed by Certificates
iSMA CONTROLLI is a long-standing member of the BACnet community. The experience in developing high quality products and the BTL (BACnet Test Laboratory) certification confirms the excellent performance of communication using the BACnet protocol.


 

Technical Specification


Hardware Specification
RS485 interface
mini USB type B interface
Status LED indicators
DIN rail mounted
24 onboard inputs

Inputs
24 Digital Inputs (DI)
Dry contact inputs
Fast pulse counter up to 100 Hz saved in EEPROM memory

Communication
BACnet MS/TP
Modbus RTU/ASCII
Free software iSMA Configurator
Dedicated Niagara Framework modules

Power Supply
24 V DC ± 20%
24 V AC ± 20%

A single controller to operate the building
Meet the next evolution in building management MAC36PRO, the latest generation of Master Application Controllers powered by Niagara. Its compact size, versatile peripherals, and robust local visualization make it the go-to stand-alone controller for effective building management.

Get ready for a performance boost!
Achieve maximum efficiency and comfort of the building while reducing the energy cost to a minimum thanks to connecting HVAC, metering, lighting, comfort and energy management into one common platform.

Visualization Efficiency
Unlock an enhanced operating experience with our latest controller features, allowing seamless HDMI-operated local visualization.

Expandable and Scalable
36 onboard inputs and outputs can be easily expanded with Multiprotocol I/O Modules by IP or RS485 interface, enabling expanding the controller capabilities at the same time of installation or in the future.

Building Management on your terms
MAC36 Controllers provides complete control, data logging, alarming, scheduling, integration, and visualization in one comprehensive package. Whether you want to remotely access your building through a secured connection or control it locally with a screen connected directly to the controller through the HDMI port, our solution gives you the flexibility and convenience you need to manage your building on your own terms.

DDC Control
Take advantage of the onboard 36 I/O managable within Niagara Framework.

16 Universal Inputs
Support for over 20 types of temperature sensors and voltage, resistance, current, and dry contact measurements on each universal input.

4 Digital Inputs
Dry contact inputs - made for monitoring. 100 Hz fast pulse counter with override function saves the real-time values to the SD card.

8 Digital Outputs
Digital outputs equipped with normally open 3 A relays allow for direct control without additional relays.

8 Analog Outputs
0-10 V DC control with 10 mA accuracy, PWM modes and a maximum load of up to 20 mA to power external relays makes the output suitable for a variety of scenarios.


Technical Specification

Hardware Specification
Powerful Quad-Core 1.6 GHz processor
64-bit iSMA OS (Linux)
2 GB RAM
Opto-isolated RS485 interface
2x independent Ethernet interfaces
2x USB 2.0 interfaces
HDMI 1.4 interface
FRAM Memory for Data Recovery Service
iSMA OS Linux Distribution
8GB micro SD card for system and user
Status LED indicators
DIN rail mounted
36 I/O onboard
Two programmable DIP switches
Two programmable rotary switches

Inputs
16x Universal Inputs (UI)
Temperature input 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000 0C, Ni 1000 20C, Ni1000 LG 2
Resistive input 0-1000 kΩ
Voltage input 0-10 V DC
Current input 0-20 mA
Dry contact input
+W9

4x Digital Inputs (DI)
Dry contact inputs
Fast pulse counter up to 100 Hz save in EEPROM memory

Outputs
8x Digital Outputs (DO)
NO relay output
Resistive load max. 3 A @ 230 V AC / 30 V DC
Inductive load max. 75 VA @ 230 V AC / 30 W @ 30 V DC

8x Analog Outputs (AO)
Output 0-10 V DC maximum load up to 20 mA
PWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz

Communication
Modbus RTU/ASCII
Modbus TCP/IP
BACnet MS/TP
BACnet IP
oBiX
SNMP
KNX IP
M-Bus IP
LON IP
TLS/SSL encryption
Built-in HTTP web server
MQTT
Over 200 available drivers for proprietary protocols

Power supply
24 V DC
24 V AC

Short Description
PN16 2-way globe valve
DN15, Kvs=2,5 and internal threaded connections
Bronze body and brass plug
Fluid temperature -10/150 °C
PN16 2-way globe valve
DN15, Kvs=2,5 and internal threaded connections
Bronze body and brass plug
Fluid temperature +2/+120 °C
PN16 2-way globe valve
DN100, Kvs=140 and internal threaded connections
Cast iron body and brass plug
Fluid temperature -5/140 °C
PN16 2-way globe valve
DN15, Kvs=4 and internal threaded connections
Cast iron body and brass plug
Fluid temperature -5/140 °C
Actuator for zone valves and terminal units.
Force 300 N and control signal 3 points and On / Off.
Power supply 24 Vac and max stroke 16 mm.

Connection with ring nut M30x1.5.
Electrothermal actuator for fancoil
For normally open valve series VPS, VPT and VPM
110 ÷ 230 Vac power supply.
Force 170 N, control signal On/Off.
Multiprotocol I/O module with 8 digital inputs.
Multiprotocol I/O module with the most common MIX of 18 inputs and outputs in building automation.
Multiprotocol I/O module made for monitoring with 24 digital inputs BACnet, and Modbus protocols.
The latest generation of Master Application Controllers powered by Niagara Framework. Its compact size, versatile peripherals, and robust local visualization make it the go-to stand-alone controller for effective building management.
Color
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Valve body
Bronze
Bronze
Cast Iron
Cast Iron
N/A
N/A
N/A
N/A
N/A
N/A
Plug
Brass
Brass
Brass
Brass
N/A
N/A
N/A
N/A
N/A
N/A
Valve type
2 way
2 way
2 way
2 way
N/A
N/A
N/A
N/A
N/A
N/A
Force [N]
N/A
N/A
N/A
N/A
300
170
N/A
N/A
N/A
N/A
Torque [Nm]
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
IP
N/A
N/A
N/A
N/A
43
44
40
40
N/A
30
Working range
N/A
N/A
N/A
N/A
0÷10 V DC, 0÷5 V DC, 2÷6 V DC, 2÷10 V DC, 5÷10 V DC, 6÷10 V DC, 4÷20 mA
N/A
N/A
N/A
N/A
N/A
Options
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Connection
Internal threaded
Internal threaded
Internal threaded
Internal threaded
N/A
N/A
N/A
N/A
N/A
N/A
Seal
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Fluid
Water
Water
Water
Water
N/A
N/A
N/A
N/A
N/A
N/A
Connection size
1/2" F (GAS UNI-ISO 228)
1/2" F (GAS UNI-ISO 228)
1/2" F (GAS UNI-ISO 228)
1/2" F (GAS UNI-ISO 228)
N/A
N/A
N/A
N/A
N/A
N/A
PN
16
16
16
16
N/A
N/A
N/A
N/A
N/A
N/A
T Fluid min [°C]
-10
2
-5
-5
N/A
N/A
N/A
N/A
N/A
N/A
T Fluid max [°C]
150
120
140
140
N/A
95
N/A
N/A
N/A
N/A
Leakage [% Kvs]
0
0
0,001
0,001
N/A
N/A
N/A
N/A
N/A
N/A
Leakage by-pass [% Kvs]
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Stroke [mm]
9,5
12
11,5
11,5
16
4
N/A
N/A
N/A
N/A
Stroke [°]
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
DN [mm]
15.0000
15.0000
15.0000
15.0000
N/A
N/A
N/A
N/A
N/A
N/A
Kvs
2.5000
2.5000
4.0000
4.0000
N/A
N/A
N/A
N/A
N/A
N/A
Kvs by-pass
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Flow max [l/h]
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Flow min [l/h]
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Max Differential Press. [kPa]
200
200
400
400
N/A
N/A
N/A
N/A
N/A
N/A
Power supply
N/A
N/A
N/A
N/A
24 V AC
230 V AC
24 V AC, 24 V DC
24 V AC, 24 V DC
24 V AC, 24 V DC
24 V AC, 24 V DC
Control signal
N/A
N/A
N/A
N/A
Proportional
On/Off
N/A
N/A
N/A
N/A
Emergency Return
N/A
N/A
N/A
N/A
No
No
N/A
N/A
N/A
N/A
Pressure plugs
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Application
N/A
N/A
N/A
N/A
for valves
for valves
N/A
N/A
N/A
N/A
Actuators type
N/A
N/A
N/A
N/A
Motoric
Electrothermal
N/A
N/A
N/A
N/A
Power [kW]
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Analog outputs
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4
N/A
8
Digital outputs
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4
N/A
8
Analog inputs
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Digital inputs
N/A
N/A
N/A
N/A
N/A
N/A
8
5
24
4
Controller type
N/A
N/A
N/A
N/A
N/A
N/A
Configurable
N/A
N/A
Programmable
Communication protocol
N/A
N/A
N/A
N/A
N/A
N/A
BACnet MS/TP, Modbus RTU/ASCII
BACnet MS/TP, Modbus RTU/ASCII
BACnet MS/TP, Modbus RTU/ASCII
BACnet MS/TP, BACnet IP, KNX, WiFi, Modbus RTU/ASCII, Modbus TCP/IP, M-Bus IP, LON, MQTT, SNMP, OPC, oBIX
Display
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Measure
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
P max [kPa]
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
P min [kPa]
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Min Differential Press. [kPa]
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Application
HVAC-R
HVAC-R
HVAC-R
HVAC-R
N/A
N/A
N/A
N/A
N/A
N/A
Inputs type
N/A
N/A
N/A
N/A
N/A
N/A
Digital
Universal, Digital
Digital
Universal, Digital
Outputs type
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Analog, Digital
N/A
Analog, Digital
Universal inputs
N/A
N/A
N/A
N/A
N/A
N/A
N/A
5
N/A
16