Remove Product Remove Product Remove Product Remove Product Remove Product Remove Product
Product
SKU
2TGB15F
2TGB15B
2TBB15T
2TBB15
MVP230
Description
The 2-3TGB.B series valves are made of cast iron body and brass plug and can be motorized with MVE.S actuators. Used for the control or interception of fluids in air conditioning, heating and heating systems, civil and industrial, and in machines for the heat treatment of products. The 3-way valves must be used exclusively as mixers. Valve body in gray cast iron (EN1561 GJL-250) and brass plug (EN12164 CW614N) with an equal percentage on the direct and linear path on the corner road and perfect seal with teflon gasket; the permissible temperature for the fluids is -5 °C / 140 °C. The stainless steel spindle seal is made with teflon gaskets compatible with water and water and glycol mixtures in the specified temperature range.
The valves of the 2-3TGB.B series can be used for the control or interception of fluids in air conditioning, heating and heating systems, civil and industrial, and in machines for the heat treatment of products. The 3-way valves must be used exclusively as mixers. Valve body in gray cast iron (EN1561 GJL-250) and brass plug (EN12164 CW614N) with an equal percentage on the direct and linear path on the corner road and perfect seal with teflon gasket; the permissible temperature for the fluids is -5 °C / 140 °C.
The 2TBB.T two-way valves 3TBB.T can be used for the control or interception of fluids in air conditioning, heating and heating systems, civil and industrial, in machines for the heat treatment of products and in water systems. hot sanitary. The 3-way valves must be used exclusively as mixers. Never use the angled corner for adjustment.
Can be driven with MVT203, MVT403 and MVT503 actuators.
The 2TBB and 3-way 3TBB two-way valves can be used for the control or interception of fluids in air conditioning, heating and heating systems, civil and industrial, in machines for the heat treatment of products and in systems for domestic hot water. The 3-way valves must be used exclusively as mixers. Never use the angled pathway for adjustment.
MVP are electro-thermal actuators and are controlled by an on-off signal or, 24Vac models only, also by pulse width modulation. Actuators are powered by the on-off control signal; power supply heats the thermostatic actuator that is moving the valve stem.
Short Description
PN16 2-way globe valve
DN15, Kvs=4 and internal threaded connections
Cast iron body and brass plug
Fluid temperature -5/140 °C
PN16 2-way globe valve
DN100, Kvs=140 and internal threaded connections
Cast iron body and brass plug
Fluid temperature -5/140 °C
PN16 2-way globe valve
DN15, Kvs=2,5 and internal threaded connections
Bronze body and brass plug
Fluid temperature +2/+120 °C
PN16 2-way globe valve
DN15, Kvs=2,5 and internal threaded connections
Bronze body and brass plug
Fluid temperature -10/150 °C
Electrothermal actuator for fancoil
For normally open valve series VPS, VPT and VPM
110 ÷ 230 Vac power supply.
Force 170 N, control signal On/Off.
Color
N/A
N/A
N/A
N/A
N/A
Valve body
Cast Iron
Cast Iron
Bronze
Bronze
N/A
Plug
Brass
Brass
Brass
Brass
N/A
Valve type
2 way
2 way
2 way
2 way
N/A
Force [N]
N/A
N/A
N/A
N/A
170
Torque [Nm]
N/A
N/A
N/A
N/A
N/A
IP
N/A
N/A
N/A
N/A
44
Working range
N/A
N/A
N/A
N/A
N/A
Options
N/A
N/A
N/A
N/A
N/A
Connection
Internal Threaded
Internal Threaded
Internal Threaded
Internal Threaded
N/A
Seal
N/A
N/A
N/A
N/A
N/A
Fluid
Water
Water
Water
Water
N/A
Connection size
1/2" F (GAS UNI-ISO 228)
1/2" F (GAS UNI-ISO 228)
1/2" F (GAS UNI-ISO 228)
1/2" F (GAS UNI-ISO 228)
N/A
PN
16
16
16
16
N/A
T Fluid min [°C]
-5
-5
2
-10
N/A
T Fluid max [°C]
140
140
120
150
95
Leakage [% Kvs]
0,001
0,001
0
0
N/A
Leakage by-pass [% Kvs]
N/A
N/A
N/A
N/A
N/A
Stroke [mm]
11,5
11,5
12
9,5
4
Stroke [°]
N/A
N/A
N/A
N/A
N/A
DN [mm]
15.0000
15.0000
15.0000
15.0000
N/A
Kvs
4.0000
4.0000
2.5000
2.5000
N/A
Kvs by-pass
N/A
N/A
N/A
N/A
N/A
Flow max [l/h]
N/A
N/A
N/A
N/A
N/A
Flow min [l/h]
N/A
N/A
N/A
N/A
N/A
Max Differential Press. [kPa]
400
400
200
200
N/A
Power supply
N/A
N/A
N/A
N/A
230 V AC
Control signal
N/A
N/A
N/A
N/A
On/Off
Emergency Return
N/A
N/A
N/A
N/A
No
Pressure plugs
N/A
N/A
N/A
N/A
N/A
Application
N/A
N/A
N/A
N/A
for valves
Actuators type
N/A
N/A
N/A
N/A
Electrothermal
Power [kW]
N/A
N/A
N/A
N/A
N/A
Analog outputs
N/A
N/A
N/A
N/A
N/A
Digital outputs
N/A
N/A
N/A
N/A
N/A
Analog inputs
N/A
N/A
N/A
N/A
N/A
Digital inputs
N/A
N/A
N/A
N/A
N/A
Controller type
N/A
N/A
N/A
N/A
N/A
Communication protocol
N/A
N/A
N/A
N/A
N/A
Display
N/A
N/A
N/A
N/A
N/A
Measure
N/A
N/A
N/A
N/A
N/A
P max [kPa]
N/A
N/A
N/A
N/A
N/A
P min [kPa]
N/A
N/A
N/A
N/A
N/A
Min Differential Press. [kPa]
N/A
N/A
N/A
N/A
N/A
Application
HVAC-R
HVAC-R
HVAC-R
HVAC-R
N/A
Inputs type
N/A
N/A
N/A
N/A
N/A
Outputs type
N/A
N/A
N/A
N/A
N/A
Universal inputs
N/A
N/A
N/A
N/A
N/A