EBV65-230-001 Qmax = 37000 l/h Energy Valve Modbus
SKU
EBV65-230-001
Smart Balancing Control Valve PN16
DN65, flanged connections
Cast iron body and brass plug
Flow rate max 37000 l/h
Equipped with p/t plugs and temperature sensors
Motorized with actuator 230 Vac
0-10 Vdc (default), 2-10 Vdc, 0-5/2-6 Vdc, 5-10/6-10 Vdc e 4-20 mA
Modbus-RTU connectivity, IP54
DN65, flanged connections
Cast iron body and brass plug
Flow rate max 37000 l/h
Equipped with p/t plugs and temperature sensors
Motorized with actuator 230 Vac
0-10 Vdc (default), 2-10 Vdc, 0-5/2-6 Vdc, 5-10/6-10 Vdc e 4-20 mA
Modbus-RTU connectivity, IP54
The smart balancing and control valve EBV system is composed by the following elements:
• smart high resolution actuator able to collect and elaborate all the data coming from sensors and the BMS (via Modbus) in order to properly position the control valve;
• flanged Globe Valve with equipercentage control characteristic equipped with pressure sensor plugs;
• a couple of high resolution pressure sensors able to continuously monitor the valve differential pressure;
• a couple of NTC 10 kOhm temperature sensors with stainless steel cases able to continuously monitor the supply and return fluid temperature.
EBV can be controlled by 2 types of signal:
Modbus command;
modulating (or proportional) with selectable range of action 0-10Vdc (default), 2-10Vdc, 0-5/2-6Vdc, 5-10/6-10Vdc and 4-20mA.
The command mode can be set via Modbus or via USB or via the dipswitches on the board.
• smart high resolution actuator able to collect and elaborate all the data coming from sensors and the BMS (via Modbus) in order to properly position the control valve;
• flanged Globe Valve with equipercentage control characteristic equipped with pressure sensor plugs;
• a couple of high resolution pressure sensors able to continuously monitor the valve differential pressure;
• a couple of NTC 10 kOhm temperature sensors with stainless steel cases able to continuously monitor the supply and return fluid temperature.
EBV can be controlled by 2 types of signal:
Modbus command;
modulating (or proportional) with selectable range of action 0-10Vdc (default), 2-10Vdc, 0-5/2-6Vdc, 5-10/6-10Vdc and 4-20mA.
The command mode can be set via Modbus or via USB or via the dipswitches on the board.
Valve body | Cast Iron |
---|---|
Plug | Brass |
PN | 16 |
T Fluid min [°C] | -10 |
T Fluid max [°C] | 120 |
Leakage [% Kvs] | 0,03 |
Valve type | Smart valve |
DN [mm] | 65.00 |
Connection | Flanged |
Fluid | Water |
Flow max [l/h] | 37,000.00 |
Flow min [l/h] | 12,000.00 |
Max Differential Press. [kPa] | 800 |
Min Differential Press. [kPa] | 35 |
Connection size | UNI EN 1092-1 |
Pressure plugs | Yes |
Application | HVAC-R |
Power supply | 230 V AC |
Emergency Return | No |
Communication protocol | Modbus RTU/ASCII |
Temperature sensors | Yes |