Language
Shopping Cart

MVE515R-2-RS

SKU
MVE515R-2-RS
Get a Quote

Multiprotocol Network actuator for PICV and Globe Valves with energy and temperature control functions, BACnet and Modbus protocols.

Force – 1500 N
Control signal – Modbus, BACnet or proportional
Power supply – 24 V AC/DC
Connection type - U-bolt
Stroke – 5-60 mm


Emergency Return – electronic fail-safe function

MVE-2-RS is a multiprotocol network actuator dedicated for PICVs, allowing direct temperature monitoring and control of supported medium. Together with Libra PICV the MVExxxx-2-RS creates a unique energy calculation solution for heating or cooling coils in air handling units and district heating plants.

Thanks to the RS-485 connectivity with Modbus RTU and BACnet MS/TP the actuator is ready for direct integration with Building Management Systems. MVE-2-RS series can also work with the standard Globe Valves, but in this configuration the energy calculation functionality is
not available.


2 NTC10K Inputs for Temperature Sensors
Support for two NTC 10 kOhm temperature sensors for supply and return fluid temperature measurement

1 Analog 0-10 V Input
Support for 0-10 V DC,2-10 V DC, 0-5/2-6 V DC, 5-10/6-10 V DC or 4-20 mA control signal selectable via DIP switch

1 Analog 2-10 V Output
Dedicated for indication of the actuator position feedback

Power Supply Output
Power supply for external devices 16 V DC, max 25 mA

2 End Points Switches (DMVE Accessory)
The end points relays switch if the valve is fully open or closed. Dry contacts auxiliary switches can be used to indicate the end position of the valve and for relay control of other devices.

Open Communication
The MVE5xxx-2-RS actuator is equipped with an RS485 interface with open protocol Modbus RTU and BACnet MS/TP communication. Up to 32 devices can be connected on one bus.

Calibration Function
The actuator is equipped with an automatic calibration function that is activated at the first start-up of the actuator. Calibration can be repeated at any time by pressing the button on the electronic board or remotely via Modbus and BACnet.

Simplified Configuration and Commissioning Process
The micro USB port facilitates local testing and a straightforward updating process, and the RS485 transceiver allows up to 32 devices to reliably communicate with the client on a single bus.

The free-of-charge MVE-2-RS Configurator tool enables configuration, commissioning, and monitoring if the actuator works properly.

Wide Range of Configuration Possibilities
MVE515R-2-RS is a new product in the well-known MVE family. It combines an open protocol communication and control functionalities with well-known configuration possibilities such as: electronic fail-safe function, user-friendly U-bolt connection, protection jackets, heaters for fluids below 0°C and wide range of linkages to other manufacturers' valves.


Technical Specification

Mechanical\Hardware Specification
Force 1500 N
Stroke 5-60 mm (30 mm for the short yoke models MVE515SR-2-RS)
U-bolt connection
RS485 interface
micro USB type B interface
Status LED indicators
Electronic fail-safe function

Inputs
2x NTC10K Inputs for Temperature Sensors
Support for NTC 10k Ohm inputs for supply and return temperature sensors

1x Analog 0-10V Input
Support for 0-10 V DC, 2-10 V DC, 0-5/2-6 V DC, 5-10/6-10 V DC or 4-20 mA control signals

Outputs
1x Analog 2-10V Output
2-10 V DC (0-100%); max load 2 mA for indication of the actuator position feedback

Power Supply Output
Power supply for external devices 16 V DC ± 0,5 V DC; max load 25 mA

2x End Points Switches in DMVE Accessory
Dry contacts outputs
Resistive load 4A max at 24 V AC/DC

Communication
Modbus RTU and BACnet MS/TP
Free software MVE-2-RS Configurator

Power Supply
22-30 V DC
24 V AC ± 20%

More Information
Power supply 24 V AC, 24 V DC
Power consumption Max. [VA] 21
Power consumption [W] 11
Force [N] 1500
IP 54
Stroke [mm] 60
Control signal Proportional, Proportional Modbus, Proportional BACnet
Working range 0÷10 V DC, 0÷5 V DC, 2÷6 V DC, 2÷10 V DC, 5÷10 V DC, 6÷10 V DC, 4÷20 mA
Emergency Return Yes
Application HVAC-R
Actuators type Motoric
Communication protocol BACnet MS/TP, Modbus RTU
T Fluid max [°C] 150